It is also possible to set a delayed image acquisition compared to the trigger signal received for both
hardware triggers. To set the delay value, simply use the slider found at the bottom of the screen using
the RIGHT/LEFT ARROW buttons.
Example:
The image acquisition is delayed by 150 ms compared to the rising edge of the trigger signal.
6.3. Bankset
The te
rm bankset
identifies the control panel used to manage the databank areas available on the
sensor.
NOTE: The bankset is the only access point to the FLASH memory installed on the sensor. During all
configuration steps in fact, a RAM type memory is used which is reset each time the device is
powered down. Therefore, when the current settings are modified, and you wish to render them
permanent, it is necessary to save the inspection tool using the bankset.
The 8 memory slots available on the sensor are displayed at the top of the screen. Each bank can
take on three different status modes (identified by 3 different colours):
Current bank (white)
Current memory slot
Free bank (green)
Free bank
Full bank (yellow)
Memory slot full. If you save a new inspection to this slot, it will overwrite the previous
version.